Lennox SLP98V Variable-Capacity Gas Furnace

 

Lennox SLP98V

Here are some of the top features of the SLP98V:

3-YEAR SAVINGS
$1,491
$2,502
vs. 75% AFUE vs. 65% AFUE

Efficiency rating of up to 98.2% AFUE can save you over $800 dollars each year*, compared to standard furnaces.

ENERGY STAR® qualified which means the furnace meets or exceeds U.S. federal guidelines for energy efficiency.

ENERGY STAR Most Efficient 2012 LogoThis product has been designated as one of the Most Efficient ENERGY STAR qualified products in 2012. Products that are recognized as the Most Efficient of ENERGY STAR in 2012 prevent greenhouse gas emissions by meeting rigorous energy efficiency performance levels set by the U.S. Environmental Protection Agency.

Explore the TechnologyPrecise Comfort™ technology adjusts fan speed, heat and airflow capacity in increments as small as 1% for the ultimate in temperature control.

Variable-capacity operation works much like the cruise control system of high-performance automobiles, automatically making adjustments as necessary to allow maximum fuel efficiency.

See the TechnologyVariable-speed motor provides a quiet and consistent flow of air for an ideal balance of temperature and humidity in your home.

See the TechnologySilentComfort™ technology delivers the ultimate in quiet, consistent heating—up to 7 times quieter than competitive models.

*This chart depicts potential energy savings you can expect from the SLP98V furnace, versus older furnaces with lower efficiency ratings. Criteria used in this example are 2,000 full-load heating hours, with a 60,000 Btuh heating design load and $1.368 ccf for gas. Your actual savings may vary, depending on the weather patterns in your local area, local fuel rates and your individual lifestyle. **icomfort Touch® Touchscreen thermostat must be installed with an icomfort-enabled indoor unit for maximum performance.

    • Natural gas operation
    • Full input rate for elevations to 2,000 ft
    • 115/1 supply voltage
    • Multi-try direct ignition with 100% lockout
    • Single-stage combination gas valve (field adjustable for operation to 10,000 ft elevation)
    • Pre-purge and post-purge
    • Differential air pressure switch to verify combustion air flow
    • Diagnostic indicator light
    • Sight glass for burner observation
    • External terminal board connection for 24-volt thermostat
    • Grounded, plug-in cord
    • 16-gauge aluminized steel combustion chamber (10 ft length)
    • High emissivity radiant tubes, 16-gauge HRS (10 ft lengths)
    • Compression coupling tube connections
    • Wire form hangers
    • Polished aluminum reflectors (10 ft lengths) that overlap for continuous reflector system
    • Aluminized steel flue gas turbulators for maximum efficiency
    • Horizontal or vertical venting
    • Painted cabinet
    • Transformer for 24-volt controls

Optional Features – Factory Installed

  • Single stage propane gas valve (field adjustable for operation to 10,000 ft elevation)
  • 208/1 supply voltage (models 50 – 175)
  • 230/1 supply voltage (models 50 – 175)

Optional Features – Field Installed

  • “U” heat exchanger tube with reflector
  • “L” heat exchanger tube(s) with reflector
  • 5-ft heat exchanger tube with reflector
  • Reflector end covers
  • Side shields
  • Hanger kit
  • Outdoor combustion air inlet kit
  • Dual vent kit
  • Multiple heater control for zoning up to 6 units
  • Flexible gas connector
  • High altitude field conversion kits (6,000 – 10,000 ft)
  • Unit-mounted thermostat bracket
  • Gas conversion kits (natural & propane)
  • Vent cap
  • Manual shutoff valve & union
  • Thermostat

 

Size Efficiency Input MBH Output MBH Number of Blowers /Fans Blower/Fan Size (In.) Minimum CFM Maximum CFM
50 N/A 50 0 N/A N/A 0 0
75 N/A 75 0 N/A N/A 0 0
100 N/A 100 0 N/A N/A 0 0
125 N/A 125 0 N/A N/A 0 0
150 N/A 150 0 N/A N/A 0 0
175 N/A 175 0 N/A N/A 0 0
200 N/A 200 0 N/A N/A 0 0
Size: Weight (lb.) Length (In.) Width (In.) Height (In.) Vent Dia
50 42 23-21/32 13-7/32 13-5/32 4″
75 42 23-21/32 13-7/32 13-5/32 4″
100 42 23-21/32 13-7/32 13-5/32 4″
125 42 23-21/32 13-7/32 13-5/32 4″
150 42 23-21/32 13-7/32 13-5/32 4″
175 42 23-21/32 13-7/32 13-5/32 4″
200 42 23-21/32 13-7/32 13-5/32 4″
Product Literature ( Adobe Acrobat Files )
Catalogs
C-IR.pdf Gas Fired Infrared, Radiant Heating Equipment – Models VR, RIH, RIHN, RIHVN, RIHL, RIHVL
Installation Manuals>Conversion Kits (CP Bulletins)
CP-VR-GC.pdf Gas conversion instructions for Model VR
Sales Flyers
f-vr.pdf Model VR – Low Intensity, Tubular Infrared Heater Flyer
Installation Manuals
I-VR.pdf Installation manual for Model VR
Marketing Catalogs
MC-IR.pdf Benefits, features and applications of Reznor Gas Fired Infrared Heaters – Models RIHL, RIHN, RIHVL, RIHVN and VR
Parts Manuals
P-VALVES.pdf Replacement Valves, Ignition Controllers, Maxitrol Components & Serial Number Lookups
P-VR-TRPA-RIH.pdf Replacement Parts – Model Series: VR, TRPA, TRP & RIH Infrared
Application Bulletins (Equipment recommendations for specific applications)
t-flux.pdf FLUX DENSITY CHART FOR TUBULAR INFRARED HEATER – Shows heating coverage for different size heaters mounted at different mounting heights
Product Submittals>Gas Fired Radiant Heaters – Models VR/RIH/RIHN/RIHVN/RIHL/RIHVL
VR_Tech_Data.pdf Model VR Tubular Low Intensity Radiant Heater Technical Data